Freescale Semiconductor /MKM34Z7 /LCD /FDSR

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as FDSR

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)FDCNT0 (0)FDCF

FDCNT=0, FDCF=0

Description

LCD Fault Detect Status Register

Fields

FDCNT

Fault Detect Counter

0 (0): No “one” samples.

1 (1): 1 “one” samples.

2 (10): 2 “one” samples.

254 (11111110): 254 “one” samples.

255 (11111111): 255 or more “one” samples. The FDCNT can overflow. Therefore, FDSWW and FDPRS must be reconfigured for proper sampling.

FDCF

Fault Detection Complete Flag

0 (0): Fault detection is not completed.

1 (1): Fault detection is completed.